Vector RD
For refrigeration applications, Vector RD offers high performance in a reliable package. Available with an ammonia resistant option. See special feature on the New Vector Vacuum Pump left column.
Details
- 0.001 mbar Ultimate Vacuum
- 100-320 litre/min
- 60-100 gram/hr Water Vapour Pumping Rate
- 3-way SAE Flare
Specifications (Laboratory & Refrigeration)
|
|
LD 5
VLD-5
VRD-90 |
LD 9
VLD-9
VRD-160 |
LD 18
VLD-18
VRD-320 |
|
|
LT 5
VLT-5 |
LT 9
VLT-9 |
LT 18
VLT-18 |
Stages |
|
2 |
2 |
2 |
Volumetric Flow/Swept Volume @ 50Hz (60Hz)* |
litre/min
m3/hr
CFM |
100 (120)
6.0 (7.2)
3.5 (4.2) |
150 (180)
9.0 (10.8)
5.3 (6.3) |
300 (360)
18.0 (21.6)
10.6 (12.7) |
Ultimate Vacuum (PP)* |
mbar |
<5x10-4 |
<5x10-4 |
<5x10-4 |
Ultimate Vacuum with Gas Ballast (PP) |
(variable) |
0.01 |
0.01 |
0.01 |
Pump Down 20 litre vessel to 0.01mbar |
min |
3.0 |
1.5 |
0.6 |
Max. Water Vapour Pumping Rate |
gram/hr |
60 |
70 |
100 |
Operating Temperature |
ºC +/- 10 |
60 |
60 |
60 |
Rotational Speed |
rpm |
1400 |
1400 |
1400 |
Motor Power 50Hz (60Hz) |
Watts |
750 (900) |
750 (900) |
750 (900) |
Weight |
kg |
21.0 |
21.0 |
24.5 |
Dimensions |
L/W/H -
mm |
540/155
/250 |
540/155
/250 |
540/155
/250 |
Suction fitting |
ISO |
KF25 |
KF25 |
KF25 |
Oil Capacity (nominal) |
cc |
1500 |
1500 |
1500 |
|
|
|
|
|
Click here to download the PDF Technical File Download